The Vertiv Liebert APS is a modular online double conversion UPS, offering the highest level of power conditioning and power protection for critical IT systems. Continuous power conditioning, zero transfer time, pure sinewave output and scalable runtime make it ideally suited to protect critical infrastructure in both centralised and edge network applications. The modular design offers maximum power availability with built-in redundancy for fault tolerance.
Vertiv™ Liebert® APS Modular UPS, 5kVA – 20kVA N+1, Double Conversion Rack/Tower VRLA 208V UPS
Features
REMOTE MANAGEMENT & ENVIRONMENTAL MONITORING: Factory installed Intellislot Unity Card and three total intellislot ports for FREE remote management, and support for environmental sensorsTrue on-line double conversionUPS Hot-swappable power and battery modulesHigh power factor 5 kVA / 4.5 kW power modulesSite configurable as single phase or three phase inputScalable up to 20 kVA N+1Fully rated @ 40°C Stand alone or rack mountable Intelligent battery modules with automatic offline capability for anomalous eventsDouble conversion efficiency: > 92%Optional 10 A charger moduleTerminal block or optional distribution moduleoutput socket
Benefits
5 kVA/4.5 kW power modules deliver enhanced active powerScalable, pay as you growarchitecture optimizesinitial investmentIntegral battery monitoring and temperature compensated charging for extended battery life and fewer replacements Fault-tolerant design allows the critical load to run on conditioned power in the unlikely event of component failure.Hot-swappable power, control and battery modules allow replacement to be carried out without distrubingthe load.Intelligent Battery System provides continuous battery monitoring and protectionOffers LIFE™ Services, real-time remote diagnosticsforproactive maintenance, decreasing the average Mean Time to Repair (MTTR)Upgradeable, even while operating in double conversion modeConfigurable input: one or three phaseDesigned for standalone or rack mount installationMultiple Power Output Distribution (POD) boxes allows for specific application connections
Brochures and Data Sheets
Specification Documentation
Manuals
White Papers
Warranties
Drawings
- Singe Line Diagram Liebert APS 15/20kVA, 10/16 Bay, 200V-240V 50Hz 3x1 Installation 1PH XFMR-Free UPS with Rack Mount MBC
- One-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200-240V 50/60Hz 1PH XFMR-Free UPS
- One-Line Diagram Liebert APS 15/20kVA 12/16 Bay, 200-240V Input/Output 50/60Hz 1Ph XMFR-Free UPS with Floor Mount MBC w/o XFMR
- One-Line Diagram Liebert APS 15/20kVA, 10/16 Bay, 200-240V, 50/60Hz 1PH XMFR-free with Rackmount MBC
- One-Line Diagram Liebert APS 15/20kVA, 10/18 Bay, 200-240V Out, 50/60Hz !Ph XMFR-Free UPS with Wallmount MBC
- One-Line Diagram Liebert APS 15/20kVA 12/16 Bay 200-240 In - 200/100-240/120V Out 50/60HZ 1PH XFMR-Based UPS with Wallmount MBC with Dual Input
- One-Line Diagram Liebert APS 15/20kVA 12/16 Bay 200-240V - 200/100-240/120 50/60Hz 1PH XFMR-Based UPS
- One-Line Diagram Liebert APS 15/20kVA 12/16 Bay 200-240VIn - 200/100-240/120V Out, 50/60Hz 1PH XFMR-Based UPS with Floormount MBC with XFMR
- One-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200-240VIn - 200/100-240/120V Out, 50/60Hz 1PH XFMR-Based UPS with Rackmount MBC
- Single-Line Diagram Liebert APS 15/20kVA 12/16 Bay 200-240VIn - 200/100-240/120V Out, 50/60Hz 1PH XFMR-Based UPS with Wallmount MBC
- One-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200-240VIn - 200/100-240/120V Out, 50/60Hz 1PH XFMR-Free UPS with Wallmount MBC
- One-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200/100-240/120V V, 50/60Hz 2PH XFMR-Free UPS
- Single-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200/100-240/120V Input/Output, 50/60Hz 2PH XFMR-Free UPS with Floormount MBC w/o XFMR
- One-Line Diagram Notes Liebert APS UPS
- One-Line Diagram Liebert APS 15/20kVA 10/16 Bay 200/100-240/120V Out, 50/60Hz 2PH XFMR-Free UPS with Rackmount MBC